Connection Block For Distrbution  Ref: RP01118/1
Plug-in module configuration: Continuity
Plug-in module test access type: Pins
Contact characteristics
Drop Wire Connector Gauge Range: 0.4 to 1.2mm diameter
Jacket Diameter: 5mm maximum diameter
Pair Connector Gauge Range: 0.4 to 1.2mm diameter
Jacket Diameter: 3mm maximum diameter
Insulation Resistance Dry Air > 1012
Damp Atmosphere (ASTM D618, Procedure F) > 1012
Salt Fog (ASTM B117) > 1012
Immersion in Water (15 days in 3% NaCI solution) > 1012
Contact Resistance: Rmaterial + Rbridge contacts +Rwire contacts > 1012
Increase in contact Resistance after Climatic Tests >2.5m
Increase in contact Resistance after 50 reinsertions >2.5m
Dielectric Strength >3,000 Vdc for 1 minute
Current Conducting Capacity: 20A, 10A per conductor, for 10 minutes, at least,
without causing deformation of the module  



Quantity:


Connection Block For Distrbution  Ref: RP01118/2
Plug-in module configuration: 230 V GDT
Plug-in module test access type: Pins
Contact characteristics
Drop Wire Connector Gauge Range: 0.4 to 1.2mm diameter
Jacket Diameter: 5mm maximum diameter
Pair Connector Gauge Range: 0.4 to 1.2mm diameter
Jacket Diameter: 3mm maximum diameter
Insulation Resistance Dry Air > 1012
Damp Atmosphere (ASTM D618, Procedure F) > 1012
Salt Fog (ASTM B117) > 1012
Immersion in Water (15 days in 3% NaCI solution) > 1012
Contact Resistance: Rmaterial + Rbridge contacts +Rwire contacts > 1012
Increase in contact Resistance after Climatic Tests >2.5m
Increase in contact Resistance after 50 reinsertions >2.5m
Dielectric Strength >3,000 Vdc for 1 minute
Current Conducting Capacity: 20A, 10A per conductor, for 10 minutes, at least,
without causing deformation of the module  



Quantity:


Connection Block For Distrbution  Ref: RP01119/1
Internal configuration: Continuity
Plug-in module test access type: Pins
Contact characteristics
Drop Wire Connector Gauge Range: 0.4 to 1.2mm diameter
Jacket Diameter: 5mm maximum diameter
Pair Connector Gauge Range: 0.4 to 1.2mm diameter
Jacket Diameter: 3mm maximum diameter
Insulation Resistance Dry Air > 1012
Damp Atmosphere (ASTM D618, Procedure F) > 1012
Salt Fog (ASTM B117) > 1012
Immersion in Water (15 days in 3% NaCI solution) > 1012
Contact Resistance: Rmaterial + Rbridge contacts +Rwire contacts > 1012
Increase in contact Resistance after Climatic Tests >2.5m
Increase in contact Resistance after 50 reinsertions >2.5m
Dielectric Strength >3,000 Vdc for 1 minute
Current Conducting Capacity: 20A, 10A per conductor, for 10 minutes, at least,
without causing deformation of the module  



Quantity:


Connection Block For Distrbution  Ref: RP01119/2
Internal configuration: 260 V GDT
Plug-in module test access type: Pins
Contact characteristics
Drop Wire Connector Gauge Range: 0.4 to 1.2mm diameter
Jacket Diameter: 5mm maximum diameter
Pair Connector Gauge Range: 0.4 to 1.2mm diameter
Jacket Diameter: 3mm maximum diameter
Insulation Resistance Dry Air > 1012
Damp Atmosphere (ASTM D618, Procedure F) > 1012
Salt Fog (ASTM B117) > 1012
Immersion in Water (15 days in 3% NaCI solution) > 1012
Contact Resistance: Rmaterial + Rbridge contacts +Rwire contacts > 1012
Increase in contact Resistance after Climatic Tests >2.5m
Increase in contact Resistance after 50 reinsertions >2.5m
Dielectric Strength >3,000 Vdc for 1 minute
Current Conducting Capacity: 20A, 10A per conductor, for 10 minutes, at least,
without causing deformation of the module  



Quantity:


Connection Block For Distrbution  Ref: RP01119/3
Internal configuration: 230 V GDT
Plug-in module test access type: Pins
Contact characteristics
Drop Wire Connector Gauge Range: 0.4 to 1.2mm diameter
Jacket Diameter: 5mm maximum diameter
Pair Connector Gauge Range: 0.4 to 1.2mm diameter
Jacket Diameter: 3mm maximum diameter
Insulation Resistance Dry Air > 1012
Damp Atmosphere (ASTM D618, Procedure F) > 1012
Salt Fog (ASTM B117) > 1012
Immersion in Water (15 days in 3% NaCI solution) > 1012
Contact Resistance: Rmaterial + Rbridge contacts +Rwire contacts > 1012
Increase in contact Resistance after Climatic Tests >2.5m
Increase in contact Resistance after 50 reinsertions >2.5m
Dielectric Strength >3,000 Vdc for 1 minute
Current Conducting Capacity: 20A, 10A per conductor, for 10 minutes, at least,
without causing deformation of the module  



Quantity:


Connection Block For Distrbution  Ref: RP01119/4
Internal configuration: RC Filter (0.68µF/22 kOhm)
Plug-in module test access type: None
Contact characteristics
Drop Wire Connector Gauge Range: 0.4 to 1.2mm diameter
Jacket Diameter: 5mm maximum diameter
Pair Connector Gauge Range: 0.4 to 1.2mm diameter
Jacket Diameter: 3mm maximum diameter
Insulation Resistance Dry Air > 1012
Damp Atmosphere (ASTM D618, Procedure F) > 1012
Salt Fog (ASTM B117) > 1012
Immersion in Water (15 days in 3% NaCI solution) > 1012
Contact Resistance: Rmaterial + Rbridge contacts +Rwire contacts > 1012
Increase in contact Resistance after Climatic Tests >2.5m
Increase in contact Resistance after 50 reinsertions >2.5m
Dielectric Strength >3,000 Vdc for 1 minute
Current Conducting Capacity: 20A, 10A per conductor, for 10 minutes, at least,
without causing deformation of the module  



Quantity:


Connection Block For Distrbution  Ref: RP01119/5
Internal configuration: RF Filter (Medium Wave: 300 to 1600 kHz)
Plug-in module test access type: None
Contact characteristics
Drop Wire Connector Gauge Range: 0.4 to 1.2mm diameter
Jacket Diameter: 5mm maximum diameter
Pair Connector Gauge Range: 0.4 to 1.2mm diameter
Jacket Diameter: 3mm maximum diameter
Insulation Resistance Dry Air > 1012
Damp Atmosphere (ASTM D618, Procedure F) > 1012
Salt Fog (ASTM B117) > 1012
Immersion in Water (15 days in 3% NaCI solution) > 1012
Contact Resistance: Rmaterial + Rbridge contacts +Rwire contacts > 1012
Increase in contact Resistance after Climatic Tests >2.5m
Increase in contact Resistance after 50 reinsertions >2.5m
Dielectric Strength >3,000 Vdc for 1 minute
Current Conducting Capacity: 20A, 10A per conductor, for 10 minutes, at least,
without causing deformation of the module  



Quantity: